SUBMIT YOUR RESEARCH
Saudi Journal of Nursing and Health Care (SJNHC)
Volume-9 | Issue-11 | 308-317
Original Research Article
A Comparative Assessment of Educational Deficits and Compliance Issues Affecting CVAD Practices among ICU Nurses in Tertiary Hospital in Eastern Province at KSA
Amara Sankara Reddy, Sarah Al Qannas, Lija Joseph Varghese, Saeed Ahmed Alnasaif, Naslabari Moorkan, Dr. Abdul Salam
Published : Nov. 4, 2026
DOI : https://doi.org/10.36348/sjnhc.2026.v09i11.002
Abstract
Background: Central venous access devices (CVADs) are essential in intensive care settings for the administration of medications, fluids, parenteral nutrition, and hemodynamic monitoring. However, safe CVAD care depends on nurses’ knowledge and adherence to evidence-based practices. Educational deficits and gaps in clinical compliance may increase the risk of CVAD-related complications and infections. Aim: This study aimed to assess intensive care unit (ICU) nurses’ knowledge of evidence-based CVAD care and their adherence to recommended CVAD care and maintenance practices. Methods: A descriptive cross-sectional study was conducted among 120 registered nurses who provided direct care to patients with CVADs in intensive care units at a tertiary hospital in the Eastern Province of the Kingdom of Saudi Arabia. Participants were selected using a convenient sampling. Data were collected using a demographic questionnaire, a 10-item knowledge questionnaire, and a 16-item CVAD practice observation checklist covering four domains: hand hygiene and aseptic technique, catheter site and dressing care, line access and hub care, and tubing, administration set, and line maintenance. Descriptive and inferential statistics were used to analyze the data. Results: The mean age of participants was 32.95 ± 7.69 years, and 91.7% were female. The mean knowledge score was 6.5 ± 1.7/10 (65%), indicating satisfactory knowledge based on the ≥60% interpretive criterion. Knowledge gaps were particularly identified regarding antimicrobial ointment use (16.7% correct), administration-set replacement intervals (36.7%), and replacement of pressure transducers and tubing (42.5%). Bedside practice demonstrated high compliance with several practices, including avoidance of unnecessary line access (100%), appropriate dressing selection (99.2%), dressing changes according to protocol (98.3%), and hub disinfection before access (95.0%). However, compliance was lower for recommended hub scrub and drying time (35.8%), hand hygiene after CVC manipulation (55.8%), maintenance of a clean, dry, and intact dressing (69.2%), and tubing changes according to protocol (68.6%). No statistically significant differences in knowledge scores were identified according to recent CVAD-specific training (p = 0.750) or nursing experience (p = 0.968). Conclusion: The findings demonstrate moderate knowledge and variable adherence to evidence-based CVAD care and maintenance practices among ICU nurses. Specific gaps were identified in both knowledge and bedside practice, particularly in time-dependent and procedural aspects of CVAD care. The findings support the need for targeted competency-based education, regular practice observation, compliance monitoring, feedback, and ongoing competency validation to strengthen adherence to evidence-based CVAD practices.
Scholars Middle East Publishers
Browse Journals
Payments
Publication Ethics
SUBMIT ARTICLE
Browse Journals
Payments
Publication Ethics
SUBMIT ARTICLE
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
© Copyright Scholars Middle East Publisher. All Rights Reserved.